Chapter 15.24 HOUSING CODE
Section 15.24.090 Light, ventilation and heating requirements.
15.24.090 Light, ventilation and heating requirements.
No person shall occupy as owner-occupant or let to another for
occupancy any dwelling or
dwelling unit, for the purpose of living therein, which does not comply with the following
requirements:
A. Every habitable room shall have at
least one window or skylight facing directly to the
outdoors. The minimum total window area, measured between stops, for every habitable room shall
be seven percent of the floor area of such room.
B. The total of openable window area
in every habitable room shall equal to at least forty-five
percent of the minimum window area size or minimum skylight type window size, as required in
subsection A of this section, except where there is supplied some other device affording adequate
ventilation and approved by the chief code enforcement officer.
C. Every bathroom and water closet compartment
shall comply with the light and ventilation
requirements for habitable rooms contained in subsections (A) and (B) of this section, except that
no window or skylight shall be required in adequately ventilated bathrooms and water closet
compartments equipped with a ventilation system approved by the chief code enforcement officer.
D. Every dwelling unit shall be supplied
with water heating facilities properly installed and
maintained in good and safe working order.
E. Every habitable room shall contain
at least one floor or wall-type electric convenience
outlet, or one supplied ceiling-type electric light fixture; and every water closet compartment,
bathroom, laundry room and public hall shall contain at least one supplied ceiling or wall-type
electric light fixture. Every such outlet and fixture shall be properly installed, shall be maintained
in good and safe working condition, and shall be connected to the source of electric power in a safe
manner.
F. Every dwelling unit shall have heating
facilities which are properly installed, are maintained
in safe and good working condition and are capable of safely and adequately heating all habitable
rooms, bathrooms and water closet compartments and every dwelling unit located therein, to a
minimum temperature of sixty-eight degrees Fahrenheit.
G. Every dwelling unit or rooming unit
to which heat is furnished from a heating plant used in
common for the purpose of heating the building shall be supplied with heat, without such undue
restriction of ventilation as to interfere with proper sanitary conditions, to provide a minimum
temperature of sixty-eight degrees Fahrenheit.
H. Every public hall and stairway in
every multiple dwelling shall be adequately lighted in
conformity with the National Electric Code.
I. Every door opening directly from a
dwelling unit to outdoor space shall have supplied
screens and a self-closing device, and every window or other device with openings to outdoor
space, used or intended to be used for ventilation, shall likewise be supplied with screens.
J. Every basement or cellar window used
or intended to be used for ventilation, and every
other opening to a basement which might provide an entry for rodents, shall be supplied with a
screen or such other device as will effectively prevent their entry. (Prior code § 11-12)